ESS GU 108kWh UPS Lithium Backup Battery
概要
ESS GU 108kWh UPS Lithium Backup Battery is built on LiFePO₄ cells at 288VDC with 107.52kWh stored, delivering up to 420A discharge. It takes over critical loads the instant mains supply fails, for data centres, telecom rooms and industrial UPS retrofits.
製品の特長
- LiFePO₄ cells at 288VDC battery voltage
- Stored energy 107.52kWh
- Up to 420A discharge for high-rate pulse loads
- Wide voltage window; CAN / RS485 interlock with the UPS host
- Rack-mounted design with modular capacity extension
製品説明
The ESS GU series lithium backup battery pairs LiFePO₄ cells with 2C / 4C high-rate discharge, taking over critical loads the moment mains power drops. It suits data centres, telecom rooms, medical sites and industrial UPS hosts.
The ESS GU 108kWh runs at 288VDC with roughly 107.52kWh usable, measures 1100×1210×1950mm and weighs about 950kg. Each cabinet is wired, insulation-tested and function-tested before shipment, so it can be specified and ordered once the load list and local grid requirements are confirmed.
- LiFePO₄ cells at 288VDC battery voltage
- Stored energy 107.52kWh
- Up to 420A discharge for high-rate pulse loads
- Wide voltage window; CAN / RS485 interlock with the UPS host
仕様
| Cell type | LiFePO₄ 磷酸铁锂 |
|---|---|
| Module configuration | 1P20S |
| Number of modules | 8 |
| Battery voltage | 288VDC |
| Single cell capacity | 216Ah |
| Battery energy | 107.52kWh |
| Voltage range | 232~280VDC |
| Max. charge current | 105A |
| Max. discharge current | 420A |
| Protection | 过充 / 过放 / 过流 / 过温 / 短路 |
| Communication | CAN / RS485 |
| Cooling method | 智能风冷 Air cooling |
| Protection level | IP20 |
| Safety certification | UN38.3, IEC62619 |
| Storage temperature | 0℃~30℃(25℃ 可存放 6 个月) |
| Working temperature | 充电 0℃~+55℃;放电 -20℃~+55℃ |
| Humidity | 0~95%RH(无凝露) |
| Max. operating altitude | <4000m(2000m 以上降额) |
| Dimensions (L×W×H) | 1100×1210×1950mm |
| Weight | 950kg |
製品FAQ
Which UPS applications suit the ESS GU 108kWh pack?
It targets data centres, telecom base stations and equipment rooms, medical equipment, rail transit and industrial-control UPS hosts — for both lithium retrofits of the DC side and new builds replacing lead-acid strings.
What about high-rate discharge?
This model delivers up to 420A discharge and 105A charge, covering short high-current UPS discharge and fast recharge.
How compatible is it with existing UPS hosts?
Battery telemetry is exchanged over CAN / RS485 and can be opened to the host protocol. Retrofit projects must first verify the UPS DC bus voltage and charge-management logic.
Space and floor loading?
Rack-mounted cabinet, 1100×1210×1950mm, roughly 950kg. Confirm floor loading for the planned row layout.
Custom builds and private labelling?
Capacity, rate, protocol, cabinet appearance and branding can all be customised — contact us for the corresponding lead time.
適合する仕様か分からない場合は?
図面・データシート・サンプルをお送りください。48時間以内にエンジニアが適合性を確認します。