ESS GU 54kWh UPS Lithium Backup Battery

概要

ESS GU 54kWh UPS Lithium Backup Battery is built on LiFePO₄ cells at 512VDC with 53.76kWh stored, delivering up to 210A discharge. It takes over critical loads the instant mains supply fails, for data centres, telecom rooms and industrial UPS retrofits.

製品の特長

  • LiFePO₄ cells at 512VDC battery voltage
  • Stored energy 53.76kWh
  • Up to 210A discharge for high-rate pulse loads
  • Wide voltage window; CAN / RS485 interlock with the UPS host
  • Rack-mounted design with modular capacity extension

製品説明

The ESS GU series lithium backup battery pairs LiFePO₄ cells with 2C / 4C high-rate discharge, taking over critical loads the moment mains power drops. It suits data centres, telecom rooms, medical sites and industrial UPS hosts.

The ESS GU 54kWh runs at 512VDC with roughly 53.76kWh usable, measures 800×1120×1800mm and weighs about 680kg. Each cabinet is wired, insulation-tested and function-tested before shipment, so it can be specified and ordered once the load list and local grid requirements are confirmed.

  • LiFePO₄ cells at 512VDC battery voltage
  • Stored energy 53.76kWh
  • Up to 210A discharge for high-rate pulse loads
  • Wide voltage window; CAN / RS485 interlock with the UPS host

仕様

Cell typeLiFePO₄ 磷酸铁锂
Module configuration1P20S
Number of modules8
Battery voltage512VDC
Single cell capacity106Ah
Battery energy53.76kWh
Voltage range464~570VDC
Max. charge current52.5A
Max. discharge current210A
Protection过充 / 过放 / 过流 / 过温 / 短路
CommunicationCAN / RS485
Cooling method智能风冷 Air cooling
Protection levelIP20
Safety certificationUN38.3, IEC62619
Storage temperature0℃~30℃(25℃ 可存放 6 个月)
Working temperature充电 0℃~+55℃;放电 -20℃~+55℃
Humidity0~95%RH(无凝露)
Max. operating altitude<4000m(2000m 以上降额)
Dimensions (L×W×H)800×1120×1800mm
Weight680kg

製品FAQ

Which UPS applications suit the ESS GU 54kWh pack?

It targets data centres, telecom base stations and equipment rooms, medical equipment, rail transit and industrial-control UPS hosts — for both lithium retrofits of the DC side and new builds replacing lead-acid strings.

What about high-rate discharge?

This model delivers up to 210A discharge and 52.5A charge, covering short high-current UPS discharge and fast recharge.

How compatible is it with existing UPS hosts?

Battery telemetry is exchanged over CAN / RS485 and can be opened to the host protocol. Retrofit projects must first verify the UPS DC bus voltage and charge-management logic.

Space and floor loading?

Rack-mounted cabinet, 800×1120×1800mm, roughly 680kg. Confirm floor loading for the planned row layout.

Custom builds and private labelling?

Capacity, rate, protocol, cabinet appearance and branding can all be customised — contact us for the corresponding lead time.