ESS GU 23kWh UPS Lithium Backup Battery

At a glance

ESS GU 23kWh UPS Lithium Backup Battery is built on LiFePO₄ cells at 348.8VDC with 23.04kWh stored, delivering up to 240A discharge. It takes over critical loads the instant mains supply fails, for data centres, telecom rooms and industrial UPS retrofits.

Key Features

  • LiFePO₄ cells at 348.8VDC battery voltage
  • Stored energy 23.04kWh
  • Up to 240A discharge for high-rate pulse loads
  • Wide voltage window; CAN / RS485 interlock with the UPS host
  • Rack-mounted design with modular capacity extension

Product Description

The ESS GU series lithium backup battery pairs LiFePO₄ cells with 2C / 4C high-rate discharge, taking over critical loads the moment mains power drops. It suits data centres, telecom rooms, medical sites and industrial UPS hosts.

The ESS GU 23kWh runs at 348.8VDC with roughly 23.04kWh usable, measures 700×1120×1150mm and weighs about 405kg. Each cabinet is wired, insulation-tested and function-tested before shipment, so it can be specified and ordered once the load list and local grid requirements are confirmed.

  • LiFePO₄ cells at 348.8VDC battery voltage
  • Stored energy 23.04kWh
  • Up to 240A discharge for high-rate pulse loads
  • Wide voltage window; CAN / RS485 interlock with the UPS host

Specifications

Cell typeLiFePO₄ 磷酸铁锂
Module configuration1P20S
Number of modules6
Battery voltage348.8VDC
Single cell capacity80Ah
Battery energy23.04kWh
Voltage range348~412VDC
Max. charge current60A
Max. discharge current240A
Protection过充 / 过放 / 过流 / 过温 / 短路
CommunicationCAN / RS485
Cooling method智能风冷 Air cooling
Protection levelIP20
Safety certificationUN38.3, IEC62619
Storage temperature0℃~30℃(25℃ 可存放 6 个月)
Working temperature充电 0℃~+55℃;放电 -20℃~+55℃
Humidity0~95%RH(无凝露)
Max. operating altitude<4000m(2000m 以上降额)
Dimensions (L×W×H)700×1120×1150mm
Weight405kg

Product FAQ

Which UPS applications suit the ESS GU 23kWh pack?

It targets data centres, telecom base stations and equipment rooms, medical equipment, rail transit and industrial-control UPS hosts — for both lithium retrofits of the DC side and new builds replacing lead-acid strings.

What about high-rate discharge?

This model delivers up to 240A discharge and 60A charge, covering short high-current UPS discharge and fast recharge.

How compatible is it with existing UPS hosts?

Battery telemetry is exchanged over CAN / RS485 and can be opened to the host protocol. Retrofit projects must first verify the UPS DC bus voltage and charge-management logic.

Space and floor loading?

Rack-mounted cabinet, 700×1120×1150mm, roughly 405kg. Confirm floor loading for the planned row layout.

Custom builds and private labelling?

Capacity, rate, protocol, cabinet appearance and branding can all be customised — contact us for the corresponding lead time.

Not sure this is the right specification?

Send us your drawing, data sheet or sample and our engineers will confirm the match within 48 hours.

Request a Quote

Related Products

Application Cases & Scenarios

View all →