● Microgrid core equipment PCS and microgrid solutions
HV DC Battery Cabinet
HV DC Battery Cabinet

ESS GU 61kWh UPS Lithium Backup Battery

At a glance

ESS GU 61kWh UPS Lithium Backup Battery is built on LiFePO₄ cells at 153.6VDC with 61.44kWh stored, delivering up to 480A discharge. It takes over critical loads the instant mains supply fails, for data centres, telecom rooms and industrial UPS retrofits.

Key Features

  • LiFePO₄ cells at 153.6VDC battery voltage
  • Stored energy 61.44kWh
  • Up to 480A discharge for high-rate pulse loads
  • Wide voltage window; CAN / RS485 interlock with the UPS host
  • Rack-mounted design with modular capacity extension

Product Description

The ESS GU series lithium backup battery pairs LiFePO₄ cells with 2C / 4C high-rate discharge, taking over critical loads the moment mains power drops. It suits data centres, telecom rooms, medical sites and industrial UPS hosts.

The ESS GU 61kWh runs at 153.6VDC with roughly 61.44kWh usable, measures 1150×1120×1500mm and weighs about 890kg. Each cabinet is wired, insulation-tested and function-tested before shipment, so it can be specified and ordered once the load list and local grid requirements are confirmed.

  • LiFePO₄ cells at 153.6VDC battery voltage
  • Stored energy 61.44kWh
  • Up to 480A discharge for high-rate pulse loads
  • Wide voltage window; CAN / RS485 interlock with the UPS host

Specifications

Cell typeLiFePO₄ 磷酸铁锂
Module configuration1P20S
Number of modules8
Battery voltage153.6VDC
Single cell capacity120Ah
Battery energy61.44kWh
Voltage range232~285VDC
Max. charge current120A
Max. discharge current480A
Protection过充 / 过放 / 过流 / 过温 / 短路
CommunicationCAN / RS485
Cooling method智能风冷 Air cooling
Protection levelIP20
Safety certificationUL1973, UN38.3
Storage temperature0℃~30℃(25℃ 可存放 6 个月)
Working temperature充电 0℃~+55℃;放电 -20℃~+55℃
Humidity0~95%RH(无凝露)
Max. operating altitude<4000m(2000m 以上降额)
Dimensions (L×W×H)1150×1120×1500mm
Weight890kg

Product FAQ

Which UPS applications suit the ESS GU 61kWh pack?

It targets data centres, telecom base stations and equipment rooms, medical equipment, rail transit and industrial-control UPS hosts — for both lithium retrofits of the DC side and new builds replacing lead-acid strings.

What about high-rate discharge?

This model delivers up to 480A discharge and 120A charge, covering short high-current UPS discharge and fast recharge.

How compatible is it with existing UPS hosts?

Battery telemetry is exchanged over CAN / RS485 and can be opened to the host protocol. Retrofit projects must first verify the UPS DC bus voltage and charge-management logic.

Space and floor loading?

Rack-mounted cabinet, 1150×1120×1500mm, roughly 890kg. Confirm floor loading for the planned row layout.

Custom builds and private labelling?

Capacity, rate, protocol, cabinet appearance and branding can all be customised — contact us for the corresponding lead time.

Not sure this is the right specification?

Send us your drawing, data sheet or sample and our engineers will confirm the match within 48 hours.